IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

leftca_pagelinks
IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx SIR 08.0056X issue No.:3
 
Status:
Current
 
Date of Issue:2011-10-18 Page 1 of 6


    
Applicant:
Pepperl+Fuchs GmbH
Lilienthalstrasse 200
68307 Mannheim
Germany


 
Equipment:ASM150 Range of Control Stations
Optional accessory:


 
Type of Protection:Flameproof and Dust


 
Marking: Ex d IIB T6 Gb (Ta -20C or -40C or 50C)
Ex tb IIIC T80C Db IP66
or with +55C Ambient
Ex d IIB T5 Gb (Ta = -20C or -40C to +55C).
Ex tb IIIC T82C Db IP66
 
Approved for issue on behalf of the IECEx
Certification Body:
D R Stubbings BA MIET

 
Position:Certification Manager


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
SIRA Certification Service
Rake Lane
Eccleston
Chester
CH4 9JN
United Kingdom


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx SIR 08.0056X
 
Date of Issue:2011-10-18Issue No.: 3
 
Page 2 of 6
 
 Manufacturer:
Pepperl+Fuchs GmbH
Lilienthalstrasse 200
68307 Mannheim
Germany


 
 Additional Manufacturing location(s):
Pepperl+Fuchs Manufacturing UK Ltd
Cornwallis Road
West Bromwich
West Midlands
B70 7DX
United Kingdom
Pepperl+Fuchs GmbH
Werk Bhl
Bussmatten 10 - 12
77815 Bhl / Baden
Germany
Pepperl+Fuchs (Manufacturing) PTE LTD
18 Ayer Rajah Crescent
Singapore 139942
Singapore
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2007-10
Edition: 5
Explosive atmospheres - Part 0:Equipment - General requirements
IEC 60079-1 : 2007-04
Edition: 6
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
IEC 61241-1 : 2004
Edition: 1
Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by enclosures "tD"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
GB/SIR/ExTR10.0029/00GB/SIR/ExTR10.0193/00GB/SIR/ExTR10.0194/00GB/SIR/ExTR10.0237/00GB/SIR/ExTR11.0244/00


Quality Assessment Report:

DE/PTB/QAR06.0008/02DE/PTB/QAR06.0015/01DE/PTB/QAR10.0008/00GB/SIR/QAR07.0004/01


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx SIR 08.0056X
 
Date of Issue:2011-10-18Issue No.: 3
 
Page 3 of 6
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 

The ASM150 Control Stations utilise an ASM 150 flameproof enclosure (approved by certificate number IECEx SIR 08.0053U, coded Ex d IIB Gb) that is fitted with various, optional, internal configurations.

 
CONDITIONS OF CERTIFICATION: YES as shown below:
 
1.The maximum constructional gap (ic) is less than that required by Table 1 of EN 60079-1: 2007 therefore,  as a result of any maintenance and/or repair, the following gaps shall be maintained
 FlamepathMaximum Gap (mm)
 Flange joint between Enclosure/Cover0.15
 


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx SIR 08.0056X
 
Date of Issue:2011-10-18Issue No.: 3
 
Page 4 of 6
 
 
EQUIPMENT(continued):
 
Range of ASM150 Control Stations
Type designationDescription - Incorporating

ASM150 Distribution Board

*

Up to two rows of twenty, single pole MCBs rated at between 3 and 63A, up to 500V.

ASM150 Switch Distribution Board

*

The single, rotary actuator mechanism that has been approved as part of the equipment covered by certificate

numbers IECEx SIR 08.0058 and IECEx SIR 08.0066.

 

*

Twelve, single pole MCBs rated between 3 A and 63A or a combination of multi-pole MCBs not exceeding the volume of twelve, single pole MCBs.

 

*

A 4-pole isolator rated at 100 A max 500 V.

ASM150 Terminal Box

*

Up to three rails of  Weidmuller WDU or SAKD 2.5N type terminals.

ASM150 Switch Disconnector

*

The single, rotary actuator mechanism that has been approved as part of the equipment covered by certificate numbers IECEx SIR 08.0058 and IECEx SIR 08.0066.

 

*

Switch disconnector and rotary switch type Kraus Naimer 3/4/6 pole KG10B, KG20B, KG32B, KG41B, KG64B, KG80, KG100, KG126, KG161, KG251 and KG316 or equivalent, rating up to 415 V, 315 A depending upon the switch type fitted.

ASM150 Control Panel

*

The single, rotary actuator mechanism that has been approved as part of the equipment covered by certificate numbers IECEx SIR 08.0058 and IECEx SIR 08.0066.

 

*

The pilot light window assemblies approved by certificate number IECEx SIR 08.0067.

The push button actuator mechanism that has been approved as part of the equipment covered by certificate numbers IECEx SIR 08.0063 and IECEx SIR 08.0066.

 

*

Various internal euipment, as defined on drawing ASM150/NB/08.

ASM150 D.O.L. Starter

 

The push button actuator mechanism that has been approved as part of the equipment covered by certificate numbers IECEx SIR 08.0063 and IECEx SIR 08.0066.

 

*

A Kraus Naimer Contactor, 30 kW, 3 Pole, rating up to 660 V, 70 A or equivalent.

ASM150 Star Delta Starter

*

The push button actuator mechanism, that has been approved as part of the equipment covered by certificate numbers IECEx SIR 08.0063 and IECEx SIR 08.0066.

 

*

A Kraus Naimer Contactor, 22 kW, 3 Pole, rating up to 660 V, 70 A or equivalent.

 
 
 


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx SIR 08.0056X
 
Date of Issue:2011-10-18Issue No.: 3
 
Page 5 of 6
 
 
DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
 
Issue 1 – this Issue introduced the following changes:
1.The company name and address was changed and alternative manufacturing sites were recognised.
2.The use of alternative label materials.
3.The addition of a Datamatrix code on the label.
Issue 2 – this Issue introduced the following change:
1.The minimum ambient temperature associated with some of these Control Station options was lowered from -20°C to -40°C; in consequence, the condition of certification dealing with pressure testing was revised and a new condition restricting the application of the -40°C limit was introduced
Issue 3 – this Issue introduced the following change:
1The option to increase the ambient temperature range from +50°C to +55°C was approved; the marking section is amended accordingly.
2When equipment with intrinsically safe inputs/outputs as defined in IEC 60079-11 is installed, the symbols for the type of protection provided may be added to the certification coding e.g. Exd iaIICGa] IIB T6 Gb
 
 


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.: IECEx SIR 08.0056X
 
Date of Issue: 2011-10-18 Issue No.: 3
 
Page 6 of 6
 
 
Additional information:
 
[
The Manufacturer shall comply with the following condition of manufacture:
1.Each ASM 150 Control station shall be subjected to a routine overpressure test for at least 10 s as required by clause 16.1 of IEC 60079-1: 2007 Ed. 6, the pressure to be applied is detailed below; there shall be no permanent deformation or damage to the enclosure:
 Minimum ambient temperature -20°C: 9.9 bar
 Minimum ambient temperature -40°C: 13.1 bar
2.The total power dissipation of the ASM 150 Control stations shall not exceed 62 W.
3.The -40°C ambient shall not be applied to enclosures that are manufactured from LM6 aluminium or enclosures that employ a window.
 
 