Date of Issue:2006-10-04 Page 1 of 3


    
Applicant:
Pelican Products Inc.
23215 Early Avenue
Torrance CA 90505
United States of America


 
Equipment:Pelican Torches
Optional accessory:


 
Type of Protection:Ex ib e / Ex ia


 
Marking: L1 #1930 - Ex ia IIC T4 IP65
Mitylite 2AAA #1900 - Ex ib e IIC T4 IP67
Mitylite 2AA #2340 - Ex ib e IIC T4 IP65
Pocket Sabrelite #1820 - Ex ib e IIC T3 IP67
M8 #8030 - Ex ib e IIC T3 IP50
M10 #8040 - Ex ib e IIC T3 IP50
Sabrelite #2000 - Ex ib e IIC T4 IP67
IECEx TSA 06.0021X
 
Approved for issue on behalf of the IECEx
Certification Body:
Ujen Singh

 
Position:Quality and Certification Manager


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
TestSafe Australia
919 Londonderry Road
Londonderry NSW 2753
Australia


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx TSA 06.0021X
 
Date of Issue:2006-10-04Issue No.: 0
 
Page 2 of 3
 
 Manufacturer:
Pelican Products Inc.
23215 Early Avenue
Torrance CA 90505
United States of America


 
 Additional Manufacturing location(s):

 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2004
Edition: 4.0
Electrical apparatus for explosive gas atmospheres - Part 0: General requirements
IEC 60079-11 : 1999
Edition: 4
Electrical apparatus for explosive gas atmospheres - Part 11: Intrinsic safety 'i'
IEC 60079-7 : 2001
Edition: 3
Electrical apparatus for explosive gas atmospheres - Part 7: Increased safety 'e'
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
AU/TSA/ExTR06.0025/00


Quality Assessment Report:

US/FMG/QAR06.0003/00


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx TSA 06.0021X
 
Date of Issue:2006-10-04Issue No.: 0
 
Page 3 of 3
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 
The torch enclosure is made of polycarbonate. A plastic face cap is fitted with a polycarbonate lens. O-rings provide sealing between the face cap and the battery enclosure. The description of the torches is shown in the table below:

Torch Model

Switch arrangement

Vent arrangement

Cell

Bulb

L1 #1930

Rubber sealed push button

No

4 LR44

LED

Mitylite 2AAA #1900

On or off by screwing face cap

No

2 AAA

Xenon gas filled bulb

Mitylite 2AA #2340

Rubber sealed push button

Vent path near the face cap

2 AA

Xenon gas filled bulb

Sabrelite #1820

On or off by screwing face cap

Capped vent hole

2 C

Xenon gas filled bulb

M8 #8030

Rubber sealed push button

A vent hole under the vinyl sleeve

3 C

Xenon gas filled bulb

M10 #8040

Rubber sealed push button

A vent hole under the vinyl sleeve

4 C

Xenon gas filled bulb

Sabrelite #2000

On or off by screwing face cap

Capped vent hole

3 C

Xenon gas filled bulb

 
SPECIFIC CONDITIONS OF USE: YES as shown below:
 

Only the Energizer Industrial (EN series) AA size and C size alkaline cells, Energizer (E series)
C size alkaline cell, Energizer (E92) AAA size, Energizer A76 BP2 alkaline cell and Vinnic L1154 cell can be used in these torches.

 