IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

leftca_pagelinks
IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx TUN 13.0004X issue No.:0

Certificate history:

 
Status:
Current
 
Date of Issue:2013-12-17 Page 1 of 3


    
Applicant:
Pepperl + Fuchs GmbH
Lilienthalstrasse 200
68307 Mannheim
Germany


 
Equipment:Segment Protector F2-SP-IC***, R5-SP-IC*** and R5SP-SP-IC***.
Optional accessory:


 
Type of Protection:Intrinsic safety, type of protection n, Equipment dust ignition protection by enclosure "t"


 
Marking:

Ex nAc [ic] IIC T4  resp. Ex nA [ic] IIC T4 Gc

Ex tb [ic] IIIC T130 °C  resp.  Ex tb [ic Dc] IIIC T130 °C Db

 
Approved for issue on behalf of the IECEx
Certification Body:
Andreas Meyer

 
Position:Head of the IECEx Certification Body


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
TÜV NORD CERT GmbH
Hanover Office
Am TÜV 1
30519 Hannover
Germany


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx TUN 13.0004X
 
Date of Issue:2013-12-17Issue No.: 0
 
Page 2 of 3
 
 Manufacturer:
Pepperl + Fuchs GmbH
Lilienthalstrasse 200
68307 Mannheim
Germany


 
 Additional Manufacturing location(s):
Pepperl + Fuchs PTE Ltd.
P+F Building
18 Ayer Rajah Crescent
Singapore 139942
Singapore
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2011
Edition: 6.0
Explosive atmospheres - Part 0: General requirements
IEC 60079-11 : 2011
Edition: 6.0
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60079-15 : 2010
Edition: 4
Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
IEC 60079-31 : 2008
Edition: 1
Explosive atmospheres – Part 31: Equipment dust ignition protection by enclosure 't'
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
DE/TUN/ExTR13.0007/00


Quality Assessment Report:

DE/PTB/QAR06.0007/03DE/PTB/QAR06.0008/05


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx TUN 13.0004X
 
Date of Issue:2013-12-17Issue No.: 0
 
Page 3 of 3
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 
For technical data see atachment.
 
CONDITIONS OF CERTIFICATION: YES as shown below:
 

1.   The Segment Protector type R5-SP-IC*** has to be erected in such a way, that corresponding 

      to IEC 60079-15 a degree of protection of at least IP 54 according to IEC 60529 is achieved. 

     The apparatus may be installed in an area of not more than pollution degree 2.

2.   The declarations of conformity, Certificates of Conformity, instruction manuals and the special

     conditions for safe use of the used cable glands and the housing must be observed. 

3.   The operation of the jumper to change Io and the jumper to activate the terminators as well as

     the connection and disconnection of energized non- intrinsically safe circuits is only permitted

     if no explosive atmosphere exists. 

4.   Using type R5-SP-IC***, all cables have to be fixed. 

5.   The signal lines of any Spur must not be connected to earth potential or the cable shield.

 

 