IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx LCI 08.0036X issue No.:3
 
Status:
Current
 
Date of Issue:2011-05-09 Page 1 of 4


    
Applicant:
TYCO THERMAL CONTROLS
307 Constitution Dr.
Menlo Park, CA 94025
United States of America


 
Electrical Apparatus:Thermostat
Optional accessory:


 
Type of Protection:d, tD


 
Marking: TYCO
Address
Type: RAYSTAT-EX-02
Serial number: ... Year of construction: ...
Ex d IIC T6
Ex tD A21 IP66 T80°C
IECEx LCI 08.0036X
WARNING - Do not open when energized
Only use copper conductors suitable for 90°C
 
Approved for issue on behalf of the IECEx
Certification Body:
Marc Gillaux

 
Position:Certification manager


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
Laboratoire Central des Industries Electriques (LCIE)
33 Avenue du General Leclerc
FR-92260 Fontenay-aux-Roses
France


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx LCI 08.0036X
 
Date of Issue:2011-05-09Issue No.: 3
 
Page 2 of 4
 
 Manufacturer:
TYCO THERMAL CONTROLS
307 Constitution Dr.
Menlo Park, CA 94025
United States of America


 
 Additional Manufacturing location(s):
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2004
Edition: 4.0
Electrical apparatus for explosive gas atmospheres - Part 0: General requirements
IEC 60079-1 : 2003
Edition: 5
Electrical apparatus for explosive gas atmospheres - Part 1: Flameproof enclosure 'd'
IEC 61241-0 : 2004
Edition: 1
Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements
IEC 61241-1 : 2004
Edition: 1
Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by enclosures "tD"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
FR/LCI/ExTR08.0042/00FR/LCI/ExTR08.0042/01FR/LCI/ExTR08.0042/02FR/LCI/ExTR08.0042/03


Quality Assessment Report:

FR/LCI/QAR08.0004/00FR/LCI/QAR08.0004/01


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx LCI 08.0036X
 
Date of Issue:2011-05-09Issue No.: 3
 
Page 3 of 4
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 

Explosion-proof thermostat with an aluminium alloy enclosure, whose internal free volume is approximately 370 cm3.

Specific parameters of the mode(s) of protection concerned:

 

- general characteristics :

  • 6V, 12V, 24V, 125V, or 250V (DC)
  • 125V, 250V, 480V or 600V (AC)
 
CONDITIONS OF CERTIFICATION: YES as shown below:
 
Ta = -40°C to +60°C
 


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx LCI 08.0036X
 
Date of Issue:2011-05-09Issue No.: 3
 
Page 4 of 4
 
 
DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
 

Modification of the manufacturing process to create the enclosure.

Update of the technical file.

Update of the protective degree : IP66

 
 








Copyright © IEC-IECEx 2013 , Geneva Switzerland. All rights reserved.