Certificate history:
This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.
This Unit verification certificate is issued as verification that the Apparatus identified on page 1, was assessed and tested and found to comply with the IEC Standard list below. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.
STANDARDS: The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:
As this is a Unit Verification Certificate, no QAR is applicable as this certificate is specific to the items listed by serial number or other unique identification.
Submersible Pump series 3000 Models are a three phase induction motor intended for connection to pumping equipment for liquids and slurries.
Maximum depth of immersion of the motor/pump is 20 m.
The motor/pump can be operated at full load at leased half the pumphousing is submerged or according to the installation drawing. Normally closed thermal detectors fitted to each of the stator windings, and connected to the motor control circuit, disconnect supply to the motor when their temperature reaches [125 ± 6] ºC or [140 ± 6] ºC according ambient temperature and gas group application.
Connection of external circuit conductors is by means of crimp connectors located in the drive-end of the stator housing. Sealing of the cable entry is by means of an integral cable gland.
The different models are defined in the descriptive documents RS6010AE rev. 2.
- The thermal detectors fitted to the stator windings shall be connected into the motor control circuit in such a manner to disconnect the supply to the motor in order to prevent the Temperature Class T4 or T3 or 150°C (group I).
- The yield stress of the fastener elements of the casing must be in accordance with indications mentioned in instruction manual.
Issue 1 Instructions update
Issue 2 :Descriptive documents updateNew manufacturer name ITT Water & Wastewater AB instead of ITT FLYGTIntroduction of the variations 3127.091, 3085.190, 8212.090 and 8213.090
Issue 3:Introduction of variation 3315.090 New manufacturer name Xylem Water Solutions AB instead ITT Water & Wastewater AB
The marking has to be completed by the following:
WARNING:DO NOT OPEN WHEN AN EXPLOSIVE GAZ ATMOSPHERE IS PRESENTDO NOT OPEN WHEN ENERGIZEDCONNECT THERMAL PROBES