Certificate No.:
IECEx BAS 11.0142 issue No.:0
 
Status:
Current
 
Date of Issue:2012-05-24 Page 1 of 3


    
Applicant:
Tyco Thermal Controls LLC
307 Constitution Drive,
Menlo Park,
CA 94025,
United States of America


 
Electrical Apparatus:TraceTek TT-TAR Leak Detection System
Optional accessory:


 
Type of Protection:Intrinsically Safe System


 
Marking:

Ex ia IIA T4

 
Approved for issue on behalf of the IECEx
Certification Body:
R S Sinclair

 
Position:General Manager


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
Baseefa
Rockhead Business Park
Staden Lane
Buxton
Derbyshire
SK17 9RZ
United Kingdom


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BAS 11.0142
 
Date of Issue:2012-05-24Issue No.: 0
 
Page 2 of 3
 
 Manufacturer:
Tyco Thermal Controls LLC
307 Constitution Drive,
Menlo Park,
CA 94025,
United States of America


 
 Additional Manufacturing location(s):
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-25 : 2010-02
Edition: 2.0
Explosive atmospheres – Part 25: Intrinsically safe electrical systems
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
GB/BAS/ExTR12.0092/00


Quality Assessment Report:

GB/BAS/QAR06.0030/03


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BAS 11.0142
 
Date of Issue:2012-05-24Issue No.: 0
 
Page 3 of 3
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 
The TraceTek TT-TAR Leak Detection System is designed to detect the presence of hydrocarbons or organic solvents that may be leaking from a storage vessel or pipe. If a leak is detected a signal is sent to the safe area equipment so that the appropriate action can be taken.

The system consists of an MTL-5541 repeater power supply (located in the safe area), a TraceTek TT-TAR Transducer and up to 4 TraceTek TT-FFS Fast Fuel Sensors, 300m of TT-5000 Hydrocarbon Sensing Cable or 300m of TT-5001 Organic Solvent Sensing Cable (located in the Hazardous area). In the event of a leak the Hazardous area equipment will relay a signal via the MTL-5541 isolator to equipment in the safe area.
 
CONDITIONS OF CERTIFICATION: NO
 
 