Certificate No.:
IECEx FMG 09.0009X issue No.:2
 
Status:
Current
 
Date of Issue:2010-08-23 Page 1 of 4


    
Applicant:
Rosemount Tank Radar AB
Gamlestadsvägen 18B
GÖTEBORG SE-40251
Sweden


 
Electrical Apparatus:MODEL 5900S Radar Level Gauge
Optional accessory:


 
Type of Protection:Intrinsically Safe


 
Marking: FISCO: Ex ia IIC Ga/Gb
Entity: Ex ia IIC Ga
Tamb = -50˚C to 80˚C
 
Approved for issue on behalf of the IECEx
Certification Body:
David W. Styrcula

 
Position:Technical Team Manager


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
FM Approvals LLC
1151 Boston-Providence Turnpike
Norwood, MA 02062
United States of America


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx FMG 09.0009X
 
Date of Issue:2010-08-23Issue No.: 2
 
Page 2 of 4
 
 Manufacturer:
Rosemount Tank Radar AB
Gamlestadsvägen 18B
GÖTEBORG SE-40251
Sweden


 
 Additional Manufacturing location(s):
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2007-10
Edition: 5
Explosive atmospheres - Part 0:Equipment - General requirements
IEC 60079-11 : 2006
Edition: 5
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60079-26 : 2006
Edition: 2
Explosive atmospheres - Part 26: Equipment with equipment protection level (EPL) Ga
IEC 60079-27 : 2005-04
Edition: 1.0
Electrical apparatus for explosive atmospheres- Part 27: Fieldbus intrinsically safe concept (FISCO) and Fieldbus non-incendive concept (FNICO)
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
US/FMG/ExTR09.0018/00US/FMG/ExTR09.0018/01


Quality Assessment Report:

NO/DNV/QAR07.0007/00


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx FMG 09.0009X
 
Date of Issue:2010-08-23Issue No.: 2
 
Page 3 of 4
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 

 

5900Sabcdefghijklmno. Radar Level Gauge.
Energy Limitation Parameters: Ui = 30V, Ii = 300mA, Pi = 1.3W, Ci = 1.1nF, Li = 1.5µH.
FISCO Limitation Parameters: Ui = 17.5V, Ii = 380mA, Pi = 5.32W, Ci = 1.1nF, Li = 1.5µH.
a = Performance: U, P, X, Z or C.
b = Safety Certification: 3, 2, F, 0, X or Z.
c = Redundancy: 2, F, 1 or Z.
d = Communication: F or Z.
e = Certification: I7, KC, KE, KF or ZZ.
f = Custody Transfer Approval: R, 0, X, Z, F, M, C, Q, G, L, S or A.
g = Level Measurement: 1 or Z.
h = Housing: A, S or Z.
i = Cable/Conduit Connections: 1, 2, G, E, M or Z.
j =    Antenna:1A1P1HG1 or G21C1F1112ZZ
k =   Antenna        Size:5, 6, 8, A or BF or X8 or XA, B, D or X3, 4, 6, 8, A or X4, 6, 8, A or X2, 0, 3, 4 or X3, 4, 6, 8 or XZ
l =    Antenna        Material:SSSSS, H, T, M or YSSSZ
m =  Tank Seal:FF or HHPFPVQAPV, PK, QV or QKPV, PK, QV or QKPV, PK, QV or QKPV, PK, QV or QKZZ
n =   Tank        Connection:5A, 6A, 8A, AA, BA, KA, LA, MB or XXWE or CL8A, 8Z, LA, LZ or XX4A, 4B, 4C, 6A, 6B, 6C, 8A, 8B or XX3A, 3B, 4A, 4B, 6A, 6B, 8A, 8B, AA, BA, IA, IB, JA, JB, KA, KB, LA, LB, 00 or XX4A, 6A, 8A, AA, 4X, 6X, 8X, AX, JA, KA, LB, MB, JX, KX, LX, MX, 00 or XX2A, 2B, 3A, 3B, 4A, 4B, HB, IA, IB, JA, JB, 00 or XX3A, 3B, 4A, 4B, 6A, 6B, 8A, 8B, IA, IB, JA, JB, KA, KB, LA, LB, 00 or XXZZ
o =   Special:0, C or X0 or X0 or X0, V or X0, 1, 2, 3 or X0 or X1 or X0, 1, 2, 3, 4 or XZ
 
CONDITIONS OF CERTIFICATION: YES as shown below:
 
1.      The enclosure contains aluminum and is considered to present a potential risk of ignition by impact or friction. Care must be taken during installation and use to prevent impact or friction.
2.      Parabolic and Array antennas with plastic surfaces may, under certain extreme conditions, generate an ignition-capable level of electrostatic charge for IIC applications. Therefore, when these antennas are used in EPL Ga, Group IIC, appropriate measures must be taken to prevent electrostatic discharge.
 


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx FMG 09.0009X
 
Date of Issue:2010-08-23Issue No.: 2
 
Page 4 of 4
 
 
DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
 

Issue 1 - Issue 1 released because of clreical mistakes found on certificate.

Issue 2 - IECEx Addendum Report issued for clerical changes made to drawings.

 
 